SHOP FOR L&L KILN PARTS

30 Amp NEMA 6-30P Power Cord - Unit is 12' Long with a Three Prong Plug and can be used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

50 Amp NEMA 6-50P Power Cord - Unit is 12' Long with a Three Prong Plug and can be used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

30 Amp NEMA 10-30P Power Cord - Unit is 12' Long with a Three Prong Plug and can be used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

30 Amp NEMA 14-30P Power Cord - Unit is 12' Long with a Four Prong Plug and is used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

50 Amp NEMA 14-50P Power Cord - Unit is 12' Long with a Four Prong Plug and can be used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

14 Pin Female Receptacle for Handheld Controls - Unit includes color coded wires for hook up in the Floor-Mounted Control Panel and is used in conjunction with the 14 Pin Male Plug

14 Pin Male Plug for Handheld Controls - Unit includes a 6' Long Cord with color coded wires at the end for hook up in the Handheld Box and is used in conjunction with the 14 Pin Female Receptacle

Ground Wire Jumper Cord for Jupiter Kiln Element Boxes - Unit is 14 AWG, precut to 8", and comes fitted with one Ring Terminal and one Fork Terminal

Power Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled, and labeled to run from the Power Connection Block to the Power Relays on all Easy-Fire Kilns with two sections at any voltage and 1 Phase Power. There are four wires per set.

Power Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled, and labeled to run from the Power Terminal Strip to the Power Relays on all Easy-Fire Kilns with two sections at any voltage and 1 Phase Power. There are four wires in a set.

Power Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled, and labeled to run from the Power Terminal Strip to the Power Relays on All Easy-Fire and School-Master Kilns with three sections at any voltage and phase power. There are six wires in a set.

Power Element Lead Wire Bottom Harness - Set of wires is precut, fitted with the appropriate terminal ends, and labeled to run from the Bottom Element Terminal Block to the Power Terminal Strip on All Three Section Easy-Fire and School-Master Kilns. There are two wires per set.

Power Element Lead Wire Bottom/Middle Harness - Set of wires is precut, fitted with the appropriate terminal ends, and labeled to run from the Bottom Element Terminal Block to the Power Terminal Strip on all Two Section kilns, or from the Middle Element Terminal Block to the Power Terminal Strip on all Three Section Easy-Fire and School-Master Kilns. There are two wires in a set.

Power Element Lead Wire Top Harness - Set of wires is precut, fitted with the appropriate terminal ends, and labeled to run from the Top Element Terminal Block to the Power Terminal Strip on All Easy-Fire and School-Master Kilns. There are two wires per set.

10 Gauge Jumper Wire - Unit is 8" Long and includes Insulation Sleaving and two Ring Terminals. This is used as a ground wire to ground the element connection box to the kiln case.

14 Gauge Ground Wire - Unit is 8" Long and includes Insulation Sleaving, one Ring Terminal, and one Fork Terminal

Wire Sleeving for Jupiter Kiln Jumper Wires - Unit is used to provide an additional layer of insulation around the Power Wires in the Element Connection Box on All Jupiter Automatic and Jupiter Manual Kilns

Element Jumper Wires - Unit is precut and fitted with the appropriate terminal ends to run from the Element Terminal Block on the Bottom Section to the Element Terminal Block on the Top Section

Element Connection Wires - Unit is precut and fitted with the appropriate terminal ends to run from the Element Terminal Block on the Top Section to the Power Terminal Strip located on the Insulation Plate

MOV Surge Suppressor for 250 Volt / 50 Amp Enclosed Power Contactors - Unit is 5mm in Diameter, absorbs the discharge energy from the inductive coil of a contactor, and can be used on All 240 Volt or 208 Volt Contactors

The L-G-MOV1/00 MOV has a mark on it of PZ390 (you have to use a magnifying glass to see this).

Attach the MOV Suppressor to the Power Contactor by using two 16-14 AWG Insulated Female Slip on Wire Terminals for 1/4" Spades, one on each end of the MOV.

50 Amp NEMA 15-50P Power Cord - Unit is a 72" Long Cord with a Four Prong Plug and is used with All Easy-Fire Kilns at any Voltage and 3 Phase Power and All J1800 & JD1800, J23 & JD23, and J230 & JD230 Kilns at any Voltage and 3 Phase Power

50 Amp NEMA 6-50P Power Cord - Unit is a 72" Long Cord with a Three Prong Plug and is used with all Easy-Fire Kilns at any Voltage and 1 Phase Power, all J1800 & JD1800, J23 & JD23, and J230 & JD230 Kilns, all Dura-Fire kilns, and many other kilns at any Voltage and 1 Phase Power (Also used for retrofit on Older Econo J1400 Series Kilns)

50 Amp Jumper Cord with Insulated Sleaving on the ends - Unit is used with DaVinci X2800-D & XB2800-D, X3200-D & XB3200-D, T2300-D & TB2300-D, and T3400-D & TB3400-D Kilns at any Voltage and Phase Power

USE #1: 50 Amp Jumper Cord - Unit is used with DaVinci X3200-D & XB3200-D and T3400-D & TB3400-D Bell-Lift Kilns at 208 Volts or 240 Volts and any Phase Power. 12 feet long.

USE #2: This can also be used as a 12 foot 6-50 single phase 50 amp power cord for Easy-Fire, School-Master, Jupiter and other kilns that are 48 amps or less and single phase.

USE #2: This is an optional cord configuration for a Liberty-Belle kiln. Make sure the correct cord is being ordered as six other options are available (see Spec-Liberty-Belle.pdf). The 14-30P cord is standard on Liberty-Belle kilns.

Red Pilot Light - Unit is used for All Manual Kiln Control Panels

#10-24 Stainless Steel Hex Nut - Unit is used for mounting the Vent Bypass Box and Contactor Plates and for the Element Terminal Bolts