15 Amp Single Receptacle - Unit is used for Older Econo J1400, J1800, and J2300 Series Kilns at any Voltage and Phase Power
SHOP KILN PARTS
SUBCATEGORIES
20 Amp Double Receptacle - Unit is used for Older Econo J2900 Series Kilns at any Voltage and Phase Power
Old Style Power Connection Board with Terminal Bolts - Unit is used on Older Econo J236, J45, and J2900 Series Kilns at any Voltage and 1 Phase Power
20 Amp Single Receptacle - Unit is used for All Newer Jupiter Automatic and Jupiter Manual Kilns at any Voltage and Phase Power
Power Terminal Strip - Unit has Two 1/4" Spade Terminals on each side and is used for the Power Wires on Liberty-Belle Kilns
MOV Surge Suppressor for 250 Volt / 50 Amp Enclosed Power Contactors - Unit is 5mm in Diameter, absorbs the discharge energy from the inductive coil of a contactor, and can be used on All 240 Volt or 208 Volt Contactors
The L-G-MOV1/00 MOV has a mark on it of PZ390 (you have to use a magnifying glass to see this).
Attach the MOV Suppressor to the Power Contactor by using two 16-14 AWG Insulated Female Slip on Wire Terminals for 1/4" Spades, one on each end of the MOV.
1 Amp NLN30 or NON30 Fuse - Unit is used with the 1 Pole 250 Volt / 30 Amp Fuse Holders
15 Amp NLN15 or NON15 Fuse - Unit is used with 600 Volt / 30 Amp Fuse Holders
2 Amp NLN2 or NON2 Fuse - Unit is used with 600 Volt / 30 Amp Fuse Holders
2 Amp NLN30 or NON30 Fuse - Unit is used with the 1 Pole 250 Volt / 30 Amp Fuse Holders
20 Amp NLN20 or NON20 Fuse - Unit is used with 600 Volt / 30 Amp Fuse Holders
30 Amp NLN30 or NON30 Fuse - Unit is used with 250 Volt / 30 Amp Fuse Holders
30 Amp NLN30 or NON30 Fuse - Unit is used with 600 Volt / 30 Amp Fuse Holders
40 Amp NLN40 or NON40 Fuse - Unit is used with 250 Volt / 60 Amp Fuse Holders
50 Amp NLN50 or NON50 Fuse - Unit is used with 250 Volt / 60 Amp Fuse Holders
60 Amp NLN60 or NON60 Fuse - Unit is used with 250 Volt / 60 Amp Fuse Holders
60 Amp NLN30 or NON60 Fuse - Unit is used with 600 Volt / 60 Amp Fuse Holders
70 Amp NLN70 Fuse - Unit is used with 250 Volt / 100 Amp Fuse Holders
90 Amp NLN70 Fuse - Unit is used with 250 Volt / 100 Amp Fuse Holders
Noise Filter for Radio Frequency Noise - This is used to filter incoming power to prevent line noise from affecting the electronic control
Mounting Kit for Old Style (Red) Element Terminal Boards - Kit includes four 1/4" high ceramic spacers and two #8 x 1-1/2" long stainless sheet metal screws.
Mounting Kit for Old Style (Red) Power Connection Boards - Kit includes all Hardware
On/Off Toggle Switch - Unit is used to switch the Control Board on and off on All Automatic Kilns
Toggle Switch Legend Plate - Unit is used in conjunction with All On/Off Toggle Switches
30 Amp Panel Mount Fuse Holder for BAN
1/2 Amp Panel Mount Fuse Holder for Control Fuse
2 Pole Power Connection Block - Units is rated for 175 Amps and is used with All Jupiter Automatic and Jupiter Manual Kilns at any Voltage and 1 Phase Power
3 Pole Power Connection Block - Units is rated for 175 Amps and is used with All Jupiter Automatic and Jupiter Manual Kilns at any Voltage and 3 Phase Power
1 Pole Power Connection Block - Unit is rated for 335 Amps and is used with DaVinci Kilns at 480 Volts or 380 Volts and 3 Phase Power that require an extra Power Connection
3 Pole Power Connection Block - Unit is rated for 335 Amps and is used with DaVinci Kilns at any Voltage and Phase Power
2 Pole Power Relay - Unit is rated for 30 Amps (resistive load below 300 Volts) with a 208 Volt Coil and is used in Older Manual Kilns and Renaissance Kilns at 208 Volts and any Phase Power
2 Pole Power Relay - Unit is rated for 30 Amps (resistive load under 300 volts) with a 240 Volt Coil and is used in Older Manual Kilns and Renaissance Kilns at 240 Volts and any Phase Power
3 Pole Power Relay - Unit is rated for 50 Amps with a 120 Volt Coil - Unit is the standard Power Relay on All X2800-D & XB2800-D, X3200-D & XB3200-D, T2300-D & TB2300-D, and T3400-D & TB3400-D Series DaVinci Kilns and Easy-Load kilns that are rated for 480 volts. (Note: the 480 volt input current is reduced to 120 volts for the control circuit that controls the coils of these contactors)
3 Pole Power Relay - Unit is rated for 50 Amps with a 240/208 Volt Coil - Unit is the standard Power Relay on All X2800-D & XB2800-D, X3200-D & XB3200-D, T2300-D & TB2300-D, and T3400-D & TB3400-D Series DaVinci Kilns and Hercules and Easy-Load kilns. These are used on kilns that have either 208 or 240 volt power.
Power Terminal Strip - Unit has Six 1/4" Spade Terminals on each side, comes with a Terminal Strip Marker Board and is used for the Power Wires on piggybacked Control Panels
SLU-70 Copper Lug used to ground an electrical circuit
#10-24 Stainless Steel Element Terminal Bolt - Unit is 1-1/4" Long and is used for all L&L kilns.
Note: past lengths used were 1-1/2" and 1-3/4" long. This is a direct replacement and should work in all situations.
#10 Stainless Steel Flat Fender Washer - This is the large diameter (3/4" OD) washer used to sandwich element ends on the element terminal.
#10-24 Stainless Steel Hex Nut - Unit is used for mounting the Vent Bypass Box and Contactor Plates and for the Element Terminal Bolts