K-X-322P/21 |
X3227-D-PB-208-1Ph |
22,047 |
208 |
Single Phase |
150 Amp |
|
- Additional Information
- Amps: 106
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 3/0 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322P/22 |
X3227-D-PB-208-3Ph |
22,047 |
208 |
Three Phase (Delta) |
90 Amp |
|
- Additional Information
- Amps: 67.4
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 2 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322P/31 |
X3227-D-PB-240-1Ph |
22,047 |
240 |
Single Phase |
125 Amp |
|
- Additional Information
- Amps: 91.9
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 1/0 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322P/32 |
X3227-D-PB-240-3Ph |
22,047 |
240 |
Three Phase (Delta) |
80 Amp |
|
- Additional Information
- Amps: 58.5
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 3 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322P/62 |
X3227-D-PB-480-3Ph |
22,047 |
460-480 |
Three Phase (Delta) |
40 Amp |
|
- Additional Information
- Amps: 28.9
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 8 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Three Elements in Wye with 277 Volts per element
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322S/62 |
X3227-D-PB-480-3Ph-QD |
22,047 |
460-480 |
Three Phase (Delta) |
40 Amp |
|
- Additional Information
- Amps: 29.2
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 8 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Two 240V Quad Elements in Series
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322P/41 |
X3227-D-PB-220-1Ph |
22,047 |
220-230 |
Single Phase |
150 Amp |
|
- Additional Information
- Amps: 100.2
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 3/0 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322P/52 |
X3227-D-PB-380-3PY |
22,047 |
380 |
Three Phase (Wye) |
60 Amp |
|
- Additional Information
- Amps: 45.5
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 6 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322P/82 |
X3227-D-PB-400-3PY |
22,047 |
400 |
Three Phase (Wye) |
60 Amp |
|
- Additional Information
- Amps: 43.6
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 6 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-X-322P/72 |
X3227-D-PB-415-3PY |
22,047 |
415 |
Three Phase (Wye) |
60 Amp |
|
- Additional Information
- Amps: 41.7
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 6 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|