K-T-233W/21 |
TB2336-D-PB-208-1Ph |
35,793 |
208 |
Single Phase |
225 Amp |
|
- Additional Information
- Amps: 172.1
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 300 mcm
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233W/22 |
TB2336-D-PB-208-3Ph |
35,793 |
208 |
Three Phase (Delta) |
150 Amp |
|
- Additional Information
- Amps: 117.3
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 3/0 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233W/31 |
TB2336-D-PB-240-1Ph |
35,793 |
240 |
Single Phase |
200 Amp |
|
- Additional Information
- Amps: 149.1
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 250 mcm
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233W/32 |
TB2336-D-PB-240-3Ph |
35,793 |
240 |
Three Phase (Delta) |
150 Amp |
|
- Additional Information
- Amps: 101.6
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 3/0 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233W/62 |
TB2336-D-PB-480-3Ph |
35,793 |
460-480 |
Three Phase (Delta) |
60 Amp |
|
- Additional Information
- Amps: 46.2
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 6 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Three Elements in Wye with 277 Volts per element
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233T/62 |
TB2336-D-PB-480-3Ph-QD |
35,793 |
460-480 |
Three Phase (Delta) |
70 Amp |
|
- Additional Information
- Amps: 50.8
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 4 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Two 240V Quad Elements in Series
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233W/41 |
TB2336-D-PB-220-1Ph |
35,793 |
220-230 |
Single Phase |
225 Amp |
|
- Additional Information
- Amps: 162.7
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 300 mcm
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233W/52 |
TB2336-D-PB-380-3PY |
35,793 |
380 |
Three Phase (Wye) |
90 Amp |
|
- Additional Information
- Amps: 69.7
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 2 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233W/82 |
TB2336-D-PB-400-3PY |
35,793 |
400 |
Three Phase (Wye) |
90 Amp |
|
- Additional Information
- Amps: 66.7
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 2 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|
K-T-233W/72 |
TB2336-D-PB-415-3PY |
35,793 |
415 |
Three Phase (Wye) |
80 Amp |
|
- Additional Information
- Amps: 63.9
- Wire Connection: Direct Wire Connection (no cord)
- Wire Gauge for Connection: 3 Ga
- Branch Fusing: Branch Fused
- Element Wiring: Parallel
- Max Temperature: Cone 10, 2350F, 1290C
- Certifications
- International: Made for all markets except EU
- CE: Not CE certified
- UL499: c-MET-us listed to UL499 Standards in the US and Canada
- Wiring Diagram(s):
|